Abstract
Accounting into the differences of heat load of the sewage emission and heat demand of the building, it is not able to satisfy the heating user only by the limited temperature difference sensible heat in many small trunk canals, a new heat pump system named urban sewage source heat pump system with freezing latent heat collection is proposed. In this system, the freezing latent heat is used as the heating source of the heat pump at peak heat load in winter as well as the sensible heat. Then the problem of the system design becomes one important issue, with the annual cost value as an evaluation criterion, it was optimized on the system design. The result shows that the new heat pump system is superior in the economy than the traditional chiller and heating network system.
Keywords
building; heat pumps; sewage treatment; building; chiller; freezing latent heat collection; heat demand; heat load; heating network system; heating source; sewage emission; trunk canals; urban sewage source heat pump system optimization design; Cooling; Heat pumps; Ice; Optimization; Resistance heating; Water heating; freezing latent heat; heat pump system; optimization; sewage;
fLanguage
English
Publisher
ieee
Conference_Titel
Mechatronic Science, Electric Engineering and Computer (MEC), 2011 International Conference on
Conference_Location
Jilin
Print_ISBN
978-1-61284-719-1
Type
conf
DOI
10.1109/MEC.2011.6025546
Filename
6025546
Link To Document