• DocumentCode
    3391635
  • Title

    Optimization design of urban sewage source heat pump system with freezing latent heat collection

  • Author

    Jianfeng Qian

  • Author_Institution
    Sch. of Energy & Civil Eng., Harbin Univ. of Commerce, Harbin, China
  • fYear
    2011
  • fDate
    19-22 Aug. 2011
  • Firstpage
    636
  • Lastpage
    639
  • Abstract
    Accounting into the differences of heat load of the sewage emission and heat demand of the building, it is not able to satisfy the heating user only by the limited temperature difference sensible heat in many small trunk canals, a new heat pump system named urban sewage source heat pump system with freezing latent heat collection is proposed. In this system, the freezing latent heat is used as the heating source of the heat pump at peak heat load in winter as well as the sensible heat. Then the problem of the system design becomes one important issue, with the annual cost value as an evaluation criterion, it was optimized on the system design. The result shows that the new heat pump system is superior in the economy than the traditional chiller and heating network system.
  • Keywords
    building; heat pumps; sewage treatment; building; chiller; freezing latent heat collection; heat demand; heat load; heating network system; heating source; sewage emission; trunk canals; urban sewage source heat pump system optimization design; Cooling; Heat pumps; Ice; Optimization; Resistance heating; Water heating; freezing latent heat; heat pump system; optimization; sewage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mechatronic Science, Electric Engineering and Computer (MEC), 2011 International Conference on
  • Conference_Location
    Jilin
  • Print_ISBN
    978-1-61284-719-1
  • Type

    conf

  • DOI
    10.1109/MEC.2011.6025546
  • Filename
    6025546