DocumentCode
3403633
Title
Applications, test data and case histories of single-phase written-poleTM motors
Author
Barber, Ronnie J. ; Morash, Richard T.
Author_Institution
Precise Power Corp., Bradenton, FL, USA
fYear
1996
fDate
22-24 Oct 1996
Firstpage
201
Lastpage
205
Abstract
Applications of large horsepower single-phase written-poleTM motors are discussed. Much of the electrical distribution in the world is single-phase. The written-pole motor has very low starting current, and runs at very high efficiency at synchronous speed and unity power factor. These characteristics make the motors ideal candidates for operating at high horsepower (over 100 HP) in single-phase applications. They can be used to replace internal combustion engines in proper niches-reducing costs for irrigation and improving reliability. The paper also presents test data obtained in the development laboratory, as well as in the field
Keywords
AC motors; machine testing; power factor; starting; high horsepower applications; irrigation costs reduction; reliability improvement; single-phase electrical distribution; single-phase written-pole motors; synchronous speed; unity power factor; very high efficiency; very low starting current; Automatic control; Computer aided software engineering; Costs; History; Irrigation; Reactive power; Surges; Synchronous motors; Testing; Torque;
fLanguage
English
Publisher
ieee
Conference_Titel
WESCON/96
Conference_Location
Anaheim, CA
ISSN
1095-791X
Print_ISBN
0-7803-3274-1
Type
conf
DOI
10.1109/WESCON.1996.553988
Filename
553988
Link To Document