• DocumentCode
    3448162
  • Title

    New technology for partial discharge testing of operating generators and motors

  • Author

    Stone, G.C. ; Sedding, H.G.

  • Author_Institution
    IRIS Power Engineering, Mississauga, Ont., Canada
  • fYear
    1993
  • fDate
    4-7 Oct 1993
  • Firstpage
    667
  • Lastpage
    672
  • Abstract
    Partial discharges (corona) are a symptom of most types of deterioration of high voltage motor and generator stator windings. A new type of partial discharge test is described. It can be performed by plant personnel during normal operation of the machine. The key requirement of the new test is to remove all the interference caused by other sparking and discharging sources in a plant. The test uses either high voltage capacitive sensors or 1000 MHz electromagnetic couplers to detect the discharge signals. The signals are processed by a specialized electronic instrument to remove noise. this test is specially designed for high speed machines
  • Keywords
    electric generators; 1000 MHz; deterioration; discharge signals; discharging; electromagnetic couplers; electronic instrument; generators; high speed machines; high voltage capacitive sensors; insulation breakdown; interference suppression; motors; partial discharge testing; personnel; sparking; stator windings; Capacitive sensors; Corona; Couplers; Electromagnetic coupling; Interference; Partial discharges; Personnel; Stator windings; Testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Electronics Insulation Conference and Electrical Manufacturing & Coil Winding Conference, 1993. Proceedings., Chicago '93 EEIC/ICWA Exposition
  • Conference_Location
    Chicago, IL
  • ISSN
    1071-6270
  • Print_ISBN
    0-7803-0847-6
  • Type

    conf

  • DOI
    10.1109/EEIC.1993.631307
  • Filename
    631307