DocumentCode :
3449678
Title :
Determination of the AC-DC Voltage Transfer Difference of High Voltage Transfer Standards at Low Frequencies
Author :
Funck, T. ; Kampik, M. ; Kessler, E. ; Klonz, M. ; Laiz, H. ; Lapuh, R.
Author_Institution :
Phys.-Technische Bundesanstalt, Braunschweig
fYear :
2004
fDate :
38139
Firstpage :
581
Lastpage :
582
Abstract :
The ac-dc transfer difference at low frequencies of thermal converters for higher voltages with planar multijunction thermal converters (PMJTCs) and series resistors has been determined by using only the established linear change of the low-frequency ac-dc current transfer difference of the PMJTC with input power. Uncertainties of less than 1 muV/V are achieved up to 1000V
Keywords :
AC-DC power convertors; measurement standards; measurement uncertainty; voltage measurement; PMJTC; ac-dc voltage transfer difference; high voltage transfer standards; measurement standards; planar multijunction thermal converters; Analog-digital conversion; Frequency conversion; Heat transfer; Metrology; Power measurement; Resistance heating; Resistors; Temperature sensors; Thermal resistance; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements Digest, 2004 Conference on
Conference_Location :
London
Print_ISBN :
0-7803-8494-6
Electronic_ISBN :
0-7803-8494-6
Type :
conf
DOI :
10.1109/CPEM.2004.305389
Filename :
4097383
Link To Document :
بازگشت