Title :
Measurements on the LANSCE upgrade H--source
Author :
Thomae, R. ; Gough, R. ; Keller, R. ; Leung, K. ; Meyer, D. ; Williams, M. ; Sanders, O. ; Ingalls, W. ; Prichard, B. ; Stevens, R.
Author_Institution :
Lawrence Berkeley Lab., CA, USA
Abstract :
For the upgrade of the Los Alamos Neutron Science Center (LANSCE) Facility, the Lawrence Berkeley National Laboratory is developing an H - ion generator that can deliver the required beam. The output current has to be 40 mA at a repetition rate of 120 Hz and a pulse length of 1 ms (12 % duty factor), and the normalized emittance must be less than 0.1 n mm mrad. During the last years, we improved the so-called surface-conversion source for the generation of higher H- currents. Experiments with magnetic filter fields have shown that the output current increases linearly with the discharge power in contrast to saturation when operating without a filter. In the latest source configuration, the filter field is generated by the cusp magnets itself, resulting in a simple and reliable setup. In this paper we present measurements on the output current as a function of discharge power. We discuss operation conditions of the source at the required 40 mA output current. Furthermore, preliminary results using 2 MHz RF power with an antenna for plasma generation are described
Keywords :
hydrogen ions; ion sources; 120 Hz; 40 mA; H; H- ion generator; H--source; cusp magnets; discharge power; filter field; normalized emittance; operation conditions; plasma generation; surface-conversion source; Antenna measurements; Current measurement; Fault location; Filters; Laboratories; Magnetic separation; Magnets; Neutrons; Plasma measurements; Surface discharges;
Conference_Titel :
Particle Accelerator Conference, 1999. Proceedings of the 1999
Conference_Location :
New York, NY
Print_ISBN :
0-7803-5573-3
DOI :
10.1109/PAC.1999.794313