• DocumentCode
    345089
  • Title

    Recalibration of a wall-current monitor using a Faraday cup for the KEKB injector linac

  • Author

    Suwada, T. ; Ohsawa, S. ; Furukawa, K. ; Akasaka, N. ; Oide, K.

  • Author_Institution
    Accel. Lab., High Energy Accel. Res. Organ., Ibaraki, Japan
  • Volume
    3
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    2238
  • Abstract
    An absolute beam-charge measurement of single-bunch electron beams with a pulse width of 10 ps and short-pulsed electron beams with a pulse width of 1 ns was performed by the beam test for the KEKB injector linac using a Faraday cup. A wall-current monitor was directly recalibrated by the beam test with an error of ±2%
  • Keywords
    calibration; charge measurement; electron accelerators; electron beams; linear accelerators; particle beam bunching; particle beam diagnostics; particle beam injection; Faraday cup; KEKB injector linac; absolute beam-charge measurement; beam test; short-pulsed electron beams; single-bunch electron beams; wall-current monitor recalibration; Calibration; Electron beams; Iron; Linear particle accelerator; Monitoring; Performance evaluation; Positrons; Pulse measurements; Space vector pulse width modulation; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1999. Proceedings of the 1999
  • Conference_Location
    New York, NY
  • Print_ISBN
    0-7803-5573-3
  • Type

    conf

  • DOI
    10.1109/PAC.1999.794432
  • Filename
    794432