Title
Recalibration of a wall-current monitor using a Faraday cup for the KEKB injector linac
Author
Suwada, T. ; Ohsawa, S. ; Furukawa, K. ; Akasaka, N. ; Oide, K.
Author_Institution
Accel. Lab., High Energy Accel. Res. Organ., Ibaraki, Japan
Volume
3
fYear
1999
fDate
1999
Firstpage
2238
Abstract
An absolute beam-charge measurement of single-bunch electron beams with a pulse width of 10 ps and short-pulsed electron beams with a pulse width of 1 ns was performed by the beam test for the KEKB injector linac using a Faraday cup. A wall-current monitor was directly recalibrated by the beam test with an error of ±2%
Keywords
calibration; charge measurement; electron accelerators; electron beams; linear accelerators; particle beam bunching; particle beam diagnostics; particle beam injection; Faraday cup; KEKB injector linac; absolute beam-charge measurement; beam test; short-pulsed electron beams; single-bunch electron beams; wall-current monitor recalibration; Calibration; Electron beams; Iron; Linear particle accelerator; Monitoring; Performance evaluation; Positrons; Pulse measurements; Space vector pulse width modulation; Testing;