DocumentCode
345410
Title
Testing of vacuum system for APT/LEDA RFQ
Author
Shen, S. ; Behne, D. ; Berg, J. ; DaCosta, T. ; Harper, M. ; Kishiyama, K. ; Valdiviez, R. ; Spinos, F. ; Schrage, D.
Author_Institution
Lawrence Livermore Nat. Lab., CA, USA
Volume
2
fYear
1999
fDate
1999
Firstpage
1333
Abstract
We have designed, built and operated two vacuum systems for the RFQ (Radio Frequency Quadrupole) in the APT/LEDA (Accelerator Production of Tritium/Low Energy Demonstration Accelerator) linac: a cryopump system for the RFQ cavity and a non-evaporable getter (NEG) pump system for the RF window system. They were designed to provide very high hydrogen pump speed (>2×104 L/s) and sorption capacity. Both systems underwent performance tests in mock assembly before the installation. This paper presents the mock test results of both vacuum systems. It also discusses the preliminary test results from the commissioning of the APT/LEDA RFQ
Keywords
accelerator cavities; cryopumping; linear accelerators; proton accelerators; APT/LEDA RFQ; RF window system; RFQ cavity; cryopump system; nonevaporable getter pump system; radio frequency quadrupole; sorption capacity; vacuum system; Assembly systems; Elementary particle vacuum; Gettering; Hydrogen; Laboratories; Linear particle accelerator; Production systems; Radio frequency; System testing; Vacuum systems;