• DocumentCode
    345410
  • Title

    Testing of vacuum system for APT/LEDA RFQ

  • Author

    Shen, S. ; Behne, D. ; Berg, J. ; DaCosta, T. ; Harper, M. ; Kishiyama, K. ; Valdiviez, R. ; Spinos, F. ; Schrage, D.

  • Author_Institution
    Lawrence Livermore Nat. Lab., CA, USA
  • Volume
    2
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    1333
  • Abstract
    We have designed, built and operated two vacuum systems for the RFQ (Radio Frequency Quadrupole) in the APT/LEDA (Accelerator Production of Tritium/Low Energy Demonstration Accelerator) linac: a cryopump system for the RFQ cavity and a non-evaporable getter (NEG) pump system for the RF window system. They were designed to provide very high hydrogen pump speed (>2×104 L/s) and sorption capacity. Both systems underwent performance tests in mock assembly before the installation. This paper presents the mock test results of both vacuum systems. It also discusses the preliminary test results from the commissioning of the APT/LEDA RFQ
  • Keywords
    accelerator cavities; cryopumping; linear accelerators; proton accelerators; APT/LEDA RFQ; RF window system; RFQ cavity; cryopump system; nonevaporable getter pump system; radio frequency quadrupole; sorption capacity; vacuum system; Assembly systems; Elementary particle vacuum; Gettering; Hydrogen; Laboratories; Linear particle accelerator; Production systems; Radio frequency; System testing; Vacuum systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1999. Proceedings of the 1999
  • Conference_Location
    New York, NY
  • Print_ISBN
    0-7803-5573-3
  • Type

    conf

  • DOI
    10.1109/PAC.1999.795539
  • Filename
    795539