• DocumentCode
    345447
  • Title

    HOMS effects in the BEPC DC separator

  • Author

    Dai, J.P. ; Chai, X.D. ; Zhao, Z.T.

  • Author_Institution
    IHEP, Beijing, China
  • Volume
    2
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    1453
  • Abstract
    During the operation of BEPC, the cable isolation layer near the high voltage connector of the DC separator is often melted, which is probably caused by the HOMs power. This paper presents the measurement results of the HOMs shunt impedance, the calculation of the power dissipated in the separator and through the connector, and the analysis of the HOMs effects
  • Keywords
    colliding beam accelerators; electron accelerators; particle beam stability; particle separators; storage rings; BEPC DC separator; HOMs shunt impedance; cable isolation layer; high voltage connector; higher order modes; Cables; Connectors; Equations; Impedance measurement; Particle separators; Power measurement; Q measurement; Storage rings; Strontium; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1999. Proceedings of the 1999
  • Conference_Location
    New York, NY
  • Print_ISBN
    0-7803-5573-3
  • Type

    conf

  • DOI
    10.1109/PAC.1999.795579
  • Filename
    795579