DocumentCode
345447
Title
HOMS effects in the BEPC DC separator
Author
Dai, J.P. ; Chai, X.D. ; Zhao, Z.T.
Author_Institution
IHEP, Beijing, China
Volume
2
fYear
1999
fDate
1999
Firstpage
1453
Abstract
During the operation of BEPC, the cable isolation layer near the high voltage connector of the DC separator is often melted, which is probably caused by the HOMs power. This paper presents the measurement results of the HOMs shunt impedance, the calculation of the power dissipated in the separator and through the connector, and the analysis of the HOMs effects
Keywords
colliding beam accelerators; electron accelerators; particle beam stability; particle separators; storage rings; BEPC DC separator; HOMs shunt impedance; cable isolation layer; high voltage connector; higher order modes; Cables; Connectors; Equations; Impedance measurement; Particle separators; Power measurement; Q measurement; Storage rings; Strontium; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1999. Proceedings of the 1999
Conference_Location
New York, NY
Print_ISBN
0-7803-5573-3
Type
conf
DOI
10.1109/PAC.1999.795579
Filename
795579
Link To Document