Title :
Development of a simplified phoswich detector configured with plastic scintillator blocks coupled to double photomultiplier tubes
Author :
Mesquita, Carlos H. ; Hamada, Margarida M. ; Rela, Paulo R.
Abstract :
The conventional phoswich detectors are configured with two dissimilar response time scintillators and need a complex electronic system. A new configuration has been devised using two similar response time scintillators. The main detector was coupled to one phototube using an acrylic light guide. The second detector, which was used as Compton-suppressor, was coupled directly to another phototube. Thus, the signals can be measured easily with lower cost and simplified electronic devices.<>
Keywords :
photomultipliers; scintillation counters; Compton-suppressor; acrylic light guide; phoswich detectors; phototube; plastic scintillator; response time; Calibration; Costs; Delay; Detectors; Optical coupling; Optical materials; Optical pulse shaping; Photoelectricity; Photomultipliers; Plastics;
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference, 1991., Conference Record of the 1991 IEEE
Conference_Location :
Santa Fe, NM, USA
Print_ISBN :
0-7803-0513-2
DOI :
10.1109/NSSMIC.1991.258890