DocumentCode :
3455997
Title :
Rise time of BC-422 plastic scintillator < 20 ps
Author :
Lerche, R.A. ; Phillon, D.W.
Author_Institution :
Lawrence Livermore Nat. Lab., CA, USA
fYear :
1991
fDate :
2-9 Nov. 1991
Firstpage :
167
Abstract :
The rise time of the plastic scintillator BC-422 has been determined to be less than 20 ps. To make the measurement, scintillator excitation was produced by X-ray pulses generated by focusing 20-ps, 2.5-TW laser pulses onto gold targets. Scintillator output was recorded with an optical streak camera whose response is 15 ps. This fast rise time identifies BC-422 as a possible radiation-to-light converter for 20-ps detectors.<>
Keywords :
luminescence of organic solids; photoluminescence; scintillation; scintillation counters; solid-state nuclear track detectors; 20 ps; BC-422; X-ray; optical streak camera; plastic scintillator; radiation-to-light converter; rise time; Electrons; Laser excitation; Laser fusion; Neutrons; Optical pulse generation; Optical recording; Plastics; Pulse measurements; Radiation detectors; Time measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium and Medical Imaging Conference, 1991., Conference Record of the 1991 IEEE
Conference_Location :
Santa Fe, NM, USA
Print_ISBN :
0-7803-0513-2
Type :
conf
DOI :
10.1109/NSSMIC.1991.258899
Filename :
258899
Link To Document :
بازگشت