• DocumentCode
    3458017
  • Title

    Measurement of plastic scintillating fiber properties with avalanche photodiodes

  • Author

    Yasuda, T. ; Grimes, A. ; Hulbert, M. ; Leedom, I.D. ; Reucroft, S.

  • Author_Institution
    Dept. of Phys., Northeastern Univ., Boston, MA, USA
  • fYear
    1991
  • fDate
    2-9 Nov. 1991
  • Firstpage
    269
  • Abstract
    Preliminary results of tests using avalanche photodiodes operated in the Geiger mode are presented. Light yields and attenuation lengths of plastic scintillating fibers of diameters 0.875 mm phi and 2 mm phi were measured with the avalanche photodiodes. The detection efficiency of the 1.5 mm phi fiber for ionizing particles is estimated based on these results.<>
  • Keywords
    avalanche photodiodes; position sensitive particle detectors; scintillation counters; 0.875 mm; 1.5 mm; 2 mm; Geiger mode; attenuation lengths; avalanche photodiodes; detection efficiency; ionizing particles; light yields; plastic scintillating fiber properties; Attenuation measurement; Avalanche photodiodes; Diodes; Length measurement; Optical attenuators; Optical fiber testing; Packaging; Plastics; Q measurement; Telescopes;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference, 1991., Conference Record of the 1991 IEEE
  • Conference_Location
    Santa Fe, NM, USA
  • Print_ISBN
    0-7803-0513-2
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1991.258978
  • Filename
    258978