DocumentCode :
3458629
Title :
Experimental research of temperature errors in acousto-optic frequency moment counter
Author :
Rozdobudko, V.V. ; Krutchinski, G.S.
Author_Institution :
Taganrog State Univ. of Radio Eng., Russia
fYear :
1999
fDate :
13-16 Sept. 1999
Firstpage :
346
Lastpage :
347
Abstract :
The results of experimental measurement of errors in an acousto-optic (AO) frequency counter are presented. This type of error is caused by temperature effect in AO deflectors (Bragg cells), which are the main elements of AO frequency counter. In the case, when input power is large, some characteristics of AO deflectors change. This causes the common mistake of AO frequency counters. AO deflectors are made of tellurium dioxide (TeO/sub 2/) and lead molybdenum tetra oxide (PbMoO/sub 4/) were tested. The construction temperature conductivity of AO deflectors was different. It is proved, that in the case AO frequency counter works with wide dynamic range of input radio signal´s power, this type of error may be equal to some percents.
Keywords :
Bragg gratings; acousto-optical deflectors; frequency meters; lead compounds; tellurium compounds; Bragg cells; PbMoO/sub 4/; TeO/sub 2/; acousto-optic frequency moment counter; dynamic range; input power; radio signal; temperature conductivity; temperature effect; temperature errors; wide dynamic range; Acoustical engineering; Apertures; Conductivity; Diffraction; Frequency measurement; Light deflectors; Organizing; Sociotechnical systems; Tellurium; Temperature;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Conference, 1999. Microwave & Telecommunication Technology. 1999 9th International Crimean [In Russian with English abstracts]
Conference_Location :
Sevastopol, Crimea, Ukraine
Print_ISBN :
966-572-003-1
Type :
conf
DOI :
10.1109/CRMICO.1999.815262
Filename :
815262