DocumentCode :
3459673
Title :
Curiosities on accurate large-signal measurements in combination with passive tuners
Author :
Bossche, Marc Vanden
Author_Institution :
NMDG Eng., Bornem, Belgium
fYear :
2003
fDate :
4-5 Dec. 2003
Firstpage :
171
Lastpage :
180
Abstract :
Since many years calibration techniques and measurement accuracy have been studied in depth for S-parameter measurements using vector network analyzers (VNA). Today, large-signal network analyzers (LSNA) are used to characterize the nonlinear behavior of components. In contrast to VNAs the stimulus cannot be switched from input to output (known as "forward mode") and vice versa ("reverse mode"). Also, LSNAs need to characterize components with source and load impedances different from 50 Ohms. These requirements demand special calibration care, even for the relative portion of the calibration process. This paper highlights some of the calibration issues without presenting an elaborate error analysis and demonstrates that accurate large-signal measurements can be performed with impedances different from 50 Ohms.
Keywords :
S-parameters; calibration; microwave measurement; network analysers; tuning; S-parameter measurements; calibration process; calibration techniques; error analysis; forward mode; large-signal measurements; large-signal vector network analyzers; load impedance; measurement accuracy; passive tuners; reverse mode; source impedance; Calibration; Current measurement; Frequency measurement; Hardware; Impedance; Phase measurement; Signal sampling; Testing; Tuners; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Measurements Conference, 2003. Fall 2003. 62nd ARFTG
Print_ISBN :
0-7803-8195-5
Type :
conf
DOI :
10.1109/ARFTGF.2003.1459769
Filename :
1459769
Link To Document :
بازگشت