  • Abstract
    Presents a novel method which provides an observer of the autonomic cardiac outflow. The originality of the method consists in the application of blind source separation to heart beat intervals (RR) and QT intervals. The reliability of the observer has been assessed on 6 subjects in experimental conditions known to elicit sympathetic or parasympathetic response
  • Keywords
    biocontrol; electrocardiography; haemodynamics; medical signal processing; neurophysiology; observers; QT intervals; RR intervals; autonomic cardiac outflow observer; blind source separation; experimental conditions; heart beat intervals; parasympathetic response; reliability assessment; sympathetic response; Blind source separation; Cardiology; Electrocardiography; Fluctuations; Hafnium; Heart beat; Heart rate interval; Laboratories; Source separation; Spectral analysis;