• DocumentCode
    3470180
  • Title

    Study on parameter estimation of hydraulic synchronous generator based on synchronous phasor measurement unit

  • Author

    Sun, Lixia ; Qu, Ping ; Gao, Yunhua ; Wu, Lei

  • Author_Institution
    Coll. of Electr. Eng., Hohai Univ., Nanjing
  • fYear
    2008
  • fDate
    6-9 April 2008
  • Firstpage
    860
  • Lastpage
    865
  • Abstract
    The premise of decoupling parameter estimation of generator to d-axis and q-axis is the rotor angle which can be measured. It applies the information obtained synchronous phasor measurement unit (PMU) to hydraulic generator parameter estimation. When the rotor angle can be obtained, it introduces ant colony optimization algorithm which can optimize the parameters of hydraulic generator described the type of fifth order model assuming only one additional circuit on the d-axis. It stresses the influence to the parameter estimation of hydraulic generator adopting different voltage regulator´s inertial amplification in the excitation system .The experiments to a hydraulic generator in some power plant are carried out by realtime digital simulator (RTDS), exporting data through power supply amplifier system and gathering measurement data from the synchronous phasor measurement unit. The results conclude that the quicker speed of excitation brings the better accuracy of the transient and the sub-transient open-circuit time constant on the parameters of q-axis, while it makes little effects on the 5 parameters of d-axis including electrical parameters and time constants.
  • Keywords
    angular measurement; digital simulation; hydraulic systems; optimisation; parameter estimation; power plants; real-time systems; synchronous generators; transients; voltage regulators; RTDS; ant colony optimization algorithm; excitation system; fifth order model; hydraulic synchronous generator; parameter estimation; phasor measurement unit; power plant; power supply amplifier system; realtime digital simulator; sub-transient open-circuit time constant; synchronous PMU; voltage regulator inertial amplification; Ant colony optimization; Circuits; Parameter estimation; Phasor measurement units; Power generation; Power system modeling; Rotors; Stress; Synchronous generators; Voltage; Ant colony optimization algorithm; Hydraulic generator; Parameter identification; Phasor measurement unit (PMU); Power system; Real-time digital simulator (RTDS);
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electric Utility Deregulation and Restructuring and Power Technologies, 2008. DRPT 2008. Third International Conference on
  • Conference_Location
    Nanjuing
  • Print_ISBN
    978-7-900714-13-8
  • Electronic_ISBN
    978-7-900714-13-8
  • Type

    conf

  • DOI
    10.1109/DRPT.2008.4523527
  • Filename
    4523527