Abstract
An image-based technique was used to track stress and strain fields in the human finger under compressional loading. Magnetic Resonance (MR) images were taken before and during compressional loading of the finger tissue. These images were used to drive nonlinear deformation of a finite element (FE) model of the tissue
Keywords
biological tissues; biomechanics; biomedical MRI; finite element analysis; image registration; kinematics; medical image processing; MRI; compressional loading; finger biomechanics; human distal phalanx; human finger; image-based technique; indentation; magnetic resonance images; strain fields tracking; stress fields tracking; Biomedical engineering; Capacitive sensors; Deformable models; Fingers; Finite element methods; Humans; Image coding; Magnetic field induced strain; Stress; Target tracking;