• DocumentCode
    3475232
  • Title

    Precision ac-dc transfer measurements with a josephson waveform synthesizer and a buffer amplifier

  • Author

    Séron, O. ; Budovsky, I. ; Djordjevic, S. ; Hagen, T. ; Behr, R. ; Palafox, L.

  • Author_Institution
    Lab. Nat. de Metrol. et d´´essais (LNE), Trappes, France
  • fYear
    2010
  • fDate
    13-18 June 2010
  • Firstpage
    30
  • Lastpage
    31
  • Abstract
    Measurements of the ac-dc difference of a thermal converter have been performed using a Josephson waveform synthesizer and a precision buffer amplifier at frequencies from 10 Hz to 4 kHz, showing agreement with conventional standards of better than 1 μV/V. Also discussed is a method of finding the operating parameters of the programmable Josephson array that correspond to minimal uncertainty.
  • Keywords
    amplifiers; convertors; measurement systems; Josephson waveform synthesizer; ac-dc transfer measurements; buffer amplifier; frequency 10 Hz to 4 kHz; programmable Josephson array; thermal converter; Analog-digital conversion; Australia; Electromagnetic measurements; Frequency conversion; Frequency measurement; Frequency synthesizers; Josephson junctions; Measurement standards; Performance evaluation; Voltage;