DocumentCode
3483469
Title
Scanned area and batch size effects on productivity for 150, 200 and 300 mm wafers
Author
Current, Michael I. ; Kindersley, Peter ; Thomases, Becca
Author_Institution
Appl. Mater., Austin, TX, USA
fYear
1996
fDate
16-21 Jun 1996
Firstpage
458
Lastpage
461
Abstract
The relationships between wafer size, wheel batch size, wheel radius, wafer packing fraction and ion beam width are explored for batch implanters designs for 150, 200 and 300 mm wafers. Analytical expressions for geometrical factors such as the scanned area fraction, the ratio of the area of Si wafers implanted to the scanned area, are derived for several batch and serial implanter geometry. The impact on the matching of process and transfer lot batch sizes on the dummy loading factors is also analysed
Keywords
batch processing (industrial); ion implantation; 150 mm; 200 mm; 300 mm; Si; batch implanter; dummy loading factor; geometrical factor; ion beam width; process lot; productivity; scanned area; serial implanter; transfer lot; wafer packing fraction; wafer size; wheel batch size; wheel radius; Batch production systems; Educational institutions; Geometry; Implants; Ion beams; Mathematics; Productivity; Spinning; Throughput; Wheels;
fLanguage
English
Publisher
ieee
Conference_Titel
Ion Implantation Technology. Proceedings of the 11th International Conference on
Conference_Location
Austin, TX
Print_ISBN
0-7803-3289-X
Type
conf
DOI
10.1109/IIT.1996.586399
Filename
586399
Link To Document