• DocumentCode
    3483469
  • Title

    Scanned area and batch size effects on productivity for 150, 200 and 300 mm wafers

  • Author

    Current, Michael I. ; Kindersley, Peter ; Thomases, Becca

  • Author_Institution
    Appl. Mater., Austin, TX, USA
  • fYear
    1996
  • fDate
    16-21 Jun 1996
  • Firstpage
    458
  • Lastpage
    461
  • Abstract
    The relationships between wafer size, wheel batch size, wheel radius, wafer packing fraction and ion beam width are explored for batch implanters designs for 150, 200 and 300 mm wafers. Analytical expressions for geometrical factors such as the scanned area fraction, the ratio of the area of Si wafers implanted to the scanned area, are derived for several batch and serial implanter geometry. The impact on the matching of process and transfer lot batch sizes on the dummy loading factors is also analysed
  • Keywords
    batch processing (industrial); ion implantation; 150 mm; 200 mm; 300 mm; Si; batch implanter; dummy loading factor; geometrical factor; ion beam width; process lot; productivity; scanned area; serial implanter; transfer lot; wafer packing fraction; wafer size; wheel batch size; wheel radius; Batch production systems; Educational institutions; Geometry; Implants; Ion beams; Mathematics; Productivity; Spinning; Throughput; Wheels;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ion Implantation Technology. Proceedings of the 11th International Conference on
  • Conference_Location
    Austin, TX
  • Print_ISBN
    0-7803-3289-X
  • Type

    conf

  • DOI
    10.1109/IIT.1996.586399
  • Filename
    586399