    Settling behavior of the bridge voltage in resistance ratio measurements with cryogenic current comparators

  • Author

    Götz, M. ; Drung, D. ; Pesel, E.

  • Author_Institution
    Phys.-Tech. Bundesanstalt Braunschweig und Berlin, Berlin, Germany
  • fYear
    2010
  • fDate
    13-18 June 2010
  • Firstpage
    573
  • Lastpage
    574
  • Abstract
    The settling of the bridge voltage in resistance comparisons based on cryogenic current comparators is investigated starting 0.2 s after current reversal and sampling at a rate of 16 Hz. For certain configurations, the result obtained for a current reversal frequency of 0.1 Hz deviates from the result when waiting tens of seconds for the decay of transients by two parts in 109, only.
  • Keywords
    comparators (circuits); cryogenic electronics; transient analysis; bridge voltage settling behavior; cryogenic current comparators; current reversal frequency; frequency 0.1 Hz; frequency 16 Hz; resistance ratio measurements; transient decay; Bridge circuits; Cables; Capacitance; Cryogenics; Current measurement; Electrical resistance measurement; Electromagnetic measurements; SQUIDs; Sampling methods; Voltage;