Title :
Enhanced field simulations and measurements of the ESD calibration setup
Author :
Leuchtmann, Pascal ; Sroka, Jan
Author_Institution :
Lab. of El.-Mag. Fields & Microwave Electron., Eidgenossische Tech. Hochschule, Zurich, Switzerland
Abstract :
Simulating the complete electromagnetic field of the calibration setup for ESD testing holds two major difficulties: (A) the relevant dimensions of the setup are both very small (millimeters) and very large (meters); and (B) the time behavior of an ESD pulse is rather fast (subnanoseconds). In the first part of this paper we present new ideas to overcome these problems. The second part deals with measurements of the target current and field quantities. A new target with flat frequency responses is used in order to overcome the drawbacks of the widely used Pellegrini target which has a resonance at 3 GHz. Comparisons between measurements and simulations are also presented
Keywords :
calibration; electric current measurement; electric field measurement; electromagnetic fields; electrostatic discharge; frequency response; magnetic field measurement; testing; 3 GHz; ESD calibration-setup; ESD pulse time behaviour; ESD testing; Pellegrini target; electromagnetic field simulation; flat frequency responses; resonance; target current measurement; Calibration; Current measurement; Electromagnetic measurements; Electronic equipment testing; Electrostatic discharge; Electrostatic measurements; IEC standards; Microwave measurements; Optical surface waves; Surface waves;
Conference_Titel :
Electromagnetic Compatibility, 2001. EMC. 2001 IEEE International Symposium on
Conference_Location :
Montreal, Que.
Print_ISBN :
0-7803-6569-0
DOI :
10.1109/ISEMC.2001.950627