DocumentCode
350198
Title
Breakdown characteristics of CO2 containing 0.125% of SF 6
Author
Önal, Emel ; Kalenderli, Özean ; Mardikyan, Kevork
Author_Institution
Fac. Electr. Eng., Istanbul Tech. Univ., Turkey
Volume
3
fYear
1999
fDate
1999
Firstpage
301
Abstract
AC breakdown strengths of CO2, SF6 and a mixture of CO2+SF6 containing 0.125% of SF6 in nonuniform field were experimentally studied. The electrode gap spacing and the relative gas pressure were varied within the range of 5-25 mm and of 100-500 kPa respectively. The experimental results have shown that the addition of SF6 to CO2 causes a significant increase of the AC breakdown voltage with respect to CO 2. Even at about pressures of 300 kPa and 25 mm gap spacing breakdown voltage of mixture were obtained 15% higher than that of pure SF6 and 54% higher than that of pure CO2
Keywords
carbon compounds; 100 to 500 kPa; 5 to 25 mm; AC breakdown strength; CO2; CO2-SF6; HV equipment; SF6; breakdown characteristics; breakdown voltage measurement; electrode gap spacing; nonuniform field; relative gas pressure;
fLanguage
English
Publisher
iet
Conference_Titel
High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
Conference_Location
London
ISSN
0537-9989
Print_ISBN
0-85296-719-5
Type
conf
DOI
10.1049/cp:19990759