DocumentCode :
350365
Title :
Influence of bio-membrane on current characteristics induced by ambient ELF magnetic field for spherical tissue model
Author :
Hayashi, Noriyuki ; Tarao, Hiroo ; Isaka, Kalsuo
Author_Institution :
Graduate Sch. of Eng. Sci., Kyushu Univ., Kasuga, Japan
Volume :
2
fYear :
1999
fDate :
1999
Firstpage :
87
Abstract :
Based on the experimental work using rats and chicken eggs, possible influences of the bio-membrane on the electric field and resultant current induced by the exposure to ambient ELF magnetic field have been pointed out. Existence of the biomembrane is, however, rarely implemented in conventional procedures of the induced current examination. The present contribution presents results of an analytical examination on how the thickness and electric conductivity of the bio-membrane affect the induced current profiles, indicating the significant role of the bio-membrane on the exact evaluation of the induced current characteristics
Keywords :
biomembranes; ambient ELF magnetic field; bio-membrane; bio-membrane thickness; biological tissue; chicken eggs; current characteristics; electric conductivity; electric field; induced current; induced current characteristics; induced current profiles; organs; rats; spherical tissue model;
fLanguage :
English
Publisher :
iet
Conference_Titel :
High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
Conference_Location :
London
ISSN :
0537-9989
Print_ISBN :
0-85296-719-5
Type :
conf
DOI :
10.1049/cp:19990602
Filename :
817236
Link To Document :