Abstract :
Sensorless winding temperature monitoring of PWM inverter-fed electrical machines may be made by a superposition method. A small dc offset current superimposed on the AC current may be used to measure winding resistances during machine operation. To obtain acceptable results, the dc voltage component in the inverter output must be measured with sufficient accuracy. Previous investigations showed that the referenced DC voltage offset is distorted by parasitic effects. A deeper knowledge of these parasitic effects is necessary. The paper describes a suitable correction method. Experimental results verify the proposed method.
Keywords :
PWM invertors; condition monitoring; electric machines; electric resistance measurement; machine windings; AC current; DC offset reference correction; PWM inverter-fed electrical machines; PWM voltage source inverters; parasitic effects; referenced DC voltage offset; sensorless winding temperature monitoring; superposition method; winding resistance measurement; Condition monitoring; Current measurement; Electrical resistance measurement; Machine windings; Pulse width modulation inverters; Sensorless control; Stator windings; Temperature measurement; Temperature sensors; Voltage control;