• DocumentCode
    3515880
  • Title

    Measurement and evaluation of the WR-28 calorimeter

  • Author

    Cui, Xiaohai ; Li, Yong ; Gao, Xiaoxun ; Dai, Mingzhen ; Zhu, Dacheng

  • Author_Institution
    Nat. Inst. of Metrol. of China, Beijing, China
  • fYear
    2011
  • fDate
    10-10 June 2011
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    We have designed and measured WR28 calorimeter which will be used as national primary power standard frequency range is 26.5-40GHz. The detail of design and measurement results was published in 2010CPEM and 74th ARFTG[1][2]. At present, the effective efficiency of WR-28 calorimeter was calculated and some uncertainty evaluations were done.
  • Keywords
    calorimeters; microwave measurement; millimetre wave measurement; CPEM; WR-28 calorimeter measurement; frequency 26.5 GHz to 40 GHz; national primary power standard frequency; uncertainty evaluation; Heating; Power measurement; Radio frequency; Thermal loading; Thermistors; Transmission line measurements; Uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Measurement Conference (ARFTG), 2011 77th ARFTG
  • Conference_Location
    Baltimore, MD
  • Print_ISBN
    978-1-61284-959-1
  • Electronic_ISBN
    978-1-61284-960-7
  • Type

    conf

  • DOI
    10.1109/ARFTG77.2011.6034569
  • Filename