• DocumentCode
    3519637
  • Title

    Characteristic analysis of transducer drive current in ultrasonic wire bonding process

  • Author

    Liu, Shaohua ; Wang, Fuliang

  • Author_Institution
    Key Lab. of Modern Complex Equip. Design & Extreme Manuf., Central South Univ., Changsha, China
  • fYear
    2009
  • fDate
    10-13 Aug. 2009
  • Firstpage
    1159
  • Lastpage
    1163
  • Abstract
    In the ultrasonic wire bonding process, the impedance change of transducer system was reflected by the current amplitude, the change of the system´s resonance frequency was represented by the change of the current´s frequency. The current signals contained much information about the bonding process and the resulted bond quality. The characteristics of current were depending on the tip states. Free, fixed, or damped tips led to different characteristics of current in some way. The bond formation process and the related physical process can be reflected by the current characteristics during bonding process. In this paper the current monitoring hardware system was set up for ultrasonic wire bonding, and the relevant software was designed. The reliable current signals had been acquired by data acquisition system and the bonding quality data was gathered by measuring the bonding shearing force. The current signals were analyzed by using the wavelet time-frequency method. Several characteristics were selected. The analysis results indicated that the frequency, the amplitude value and the change tendency of current signals are related to the bonding quality in certain extent. The fundamental resonance frequency deviation, very small current, and exceptional current changing tendency always mean failed bond.
  • Keywords
    characteristics measurement; data acquisition; lead bonding; ultrasonic bonding; ultrasonic transducers; bonding shearing force; characteristic analysis; data acquisition; drive current; impedance change; transducer; ultrasonic wire bonding; wavelet time-frequency method; Bonding forces; Bonding processes; Force measurement; Impedance; Resonance; Resonant frequency; Signal analysis; Signal processing; Ultrasonic transducers; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronic Packaging Technology & High Density Packaging, 2009. ICEPT-HDP '09. International Conference on
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4244-4658-2
  • Electronic_ISBN
    978-1-4244-4659-9
  • Type

    conf

  • DOI
    10.1109/ICEPT.2009.5270610
  • Filename
    5270610