DocumentCode
3520176
Title
Investigation of detector light response modeling for a thick continuous slab detector
Author
Miyaoka, R.S. ; Lee, K.
Author_Institution
Dept. of Radiol., Washington Univ., Seattle, WA, USA
Volume
4
fYear
2004
fDate
16-22 Oct. 2004
Firstpage
2479
Abstract
We investigate a method to improve the position decoding for thick crystal versions (i.e., ≥8 mm) of our continuous miniature crystal element (cMiCE) PET detector by more accurately modeling the detector´s light response function (LRF). The LRF for continuous detectors varies with the depth of interaction (DOI) of the detected photon. This variation of the LRF can result in a positioning error for two-dimensional positioning algorithms. The effect is greatest for photons interacting directly over a PMT channel or near the edge of the crystal. We explore a method to improve positioning performance by deriving two look up tables (LUTs), from the collected data, corresponding to the front and back regions of the crystal. The DETECT2000 simulation package was used to investigate the light response characteristics for a 48.8 mm by 48.8 mm by 10 (8) mm slab of LSO coupled to a 64 channel, flat panel PMT. Using DETECT2000 the light collected for each PMT channel versus interaction location in three dimensions is known. The data are then combined to produce the two dimensional light collection histograms that one would experimentally measure. Light collection histograms that have markedly non-Gaussian distributions (e.g., bimodal or have a high-end tail) are characterized as a combination of two Gaussian functions, where each Gaussian function corresponds to a DOI region of the crystal. The results indicate modest gains in positioning accuracy are achieved near the central region of the crystal. However, significant improvements in spatial resolution and positioning bias are achieved for the corner section of the detector.
Keywords
photomultipliers; position sensitive particle detectors; positron emission tomography; solid scintillation detectors; table lookup; 10 mm; 48.8 mm; 8 mm; DETECT2000 simulation package; DOI region; Gaussian functions; PMT channel; cMiCE PET detector; continuous miniature crystal element; depth of interaction; detector light response function; flat panel PMT; look up tables; nonGaussian distributions; position decoding; positioning error; spatial resolution; thick continuous slab detector; thick crystal versions; two dimensional light collection histograms; two-dimensional positioning algorithms; Decoding; Detectors; Histograms; Optical coupling; Packaging; Photonic crystals; Positron emission tomography; Probability distribution; Slabs; Table lookup;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2004 IEEE
ISSN
1082-3654
Print_ISBN
0-7803-8700-7
Type
conf
DOI
10.1109/NSSMIC.2004.1462758
Filename
1462758
Link To Document