Title
A high head pumped storage power plant rehabilitation project
Author
Nakamura, Kentaro ; Shigenobu, T. ; Harada, Shingo ; Muraki, Tomoya
Author_Institution
Rotating Machine Technol. R&D Dept., Toshiba Corp. Power Syst. Co., Yokohama, Japan
fYear
2012
fDate
11-14 Nov. 2012
Firstpage
1
Lastpage
6
Abstract
This paper presents the development of hydraulic performance in a high head Francis pump-turbine runner which is adopted at pumped storage power plant. In order to achieve the improvements of turbine efficiency, pump efficiency and cavitation performance for turbine and pump mode throughout a wide operating range, a new runner was designed by the latest Computational Fluid Dynamics (CFD) analysis. The validity of the new design method was evaluated by the model performance tests and this model is going to be adopted the prototype pump-turbine plant “Ohira Pumped Storage Power Plant” for Kyushu Electric Power Co., Inc.. The total maximum pump head is 546m and maximum turbine output is 256MW. The results were confirmed that the optimized runner presented extremely better anti-cavitation and high efficiency performance at both operation modes compared with the existing design runner.
Keywords
computational fluid dynamics; hydraulic turbines; hydroelectric generators; pumped-storage power stations; CFD; Kyushu Electric Power Company Incorporated; Ohira pumped storage power plant; cavitation performance; computational fluid dynamics analysis; high head Francis pump-turbine runner plant optimization; high head pumped storage power plant rehabilitation project; hydraulic performance development; power 256 MW; pump efficiency; size 546 m; turbine efficiency improvement; Blades; Computational fluid dynamics; Hydraulic turbines; Optimization; Pumps; CFD; optimization; pump-turbine runner;
fLanguage
English
Publisher
ieee
Conference_Titel
Renewable Energy Research and Applications (ICRERA), 2012 International Conference on
Conference_Location
Nagasaki
Print_ISBN
978-1-4673-2328-4
Electronic_ISBN
978-1-4673-2329-1
Type
conf
DOI
10.1109/ICRERA.2012.6477312