Abstract :
A 3 kW AC/DC converter is studied to comply the following conditions: power factor correction, output voltage regulation, electrical insulation, high efficiency. In this study we are interested in current-source resonant converter topologies with two energy storage elements and electrical insulation which allow the leakage inductance of a transformer to be included in order to achieve smaller size and lighter weight
Keywords :
AC-DC power convertors; energy storage; inductance; power factor correction; resonant power convertors; transformers; voltage control; 3 kW; AC/DC converter; current-source resonant converter; electrical insulation; energy storage elements; high efficiency; output voltage regulation; power factor correction; transformer leakage inductance; Circuit topology; Dielectrics and electrical insulation; Inductance; Power factor correction; Power transformer insulation; RLC circuits; Reactive power; Rectifiers; Resonance; Voltage control;