DocumentCode
3532145
Title
Comparison of list-mode and DIRECT approaches for time-of-flight PET reconstruction
Author
Daube-Witherspoon, Margaret E. ; Matej, Samuel ; Werner, Matthew E. ; Surti, Suleman ; Karp, Joel S.
Author_Institution
Dept. of Radiol., Univ. of Pennsylvania, Fairfax Station, VA, USA
fYear
2010
fDate
Oct. 30 2010-Nov. 6 2010
Firstpage
2252
Lastpage
2258
Abstract
Early clinical results with time-of-flight (TOF) PET systems have demonstrated the advantages of TOF information in PET reconstruction. Reconstruction approaches in TOF-PET systems include list-mode and binned iterative algorithms as well as confidence-weighted analytic methods. List-mode iterative TOF reconstruction retains the full accuracy of the data in the spatial and temporal domains but is computationally intensive. We have developed an approach [DIRECT (direct image reconstruction for TOF)] to speed up TOF reconstruction that takes advantage of the reduced angular sampling requirement of TOF data by grouping list-mode data into a small number of azimuthal views and co-polar tilts and depositing the grouped events into histo-images, arrays with the sampling and geometry of the final image. All physical effects are included in the system model and deposited in the same histo-image structure. Using histo-images allows efficient computation during reconstruction without ray-tracing or interpolation operations. The DIRECT approach was compared with the 3D list-mode TOF ordered subsets expectation maximization (OSEM) reconstruction for phantom and patient data taken on the UPenn prototype LaBr3 TOF-PET scanner. The total reconstruction time with DIRECT for data with 430-ps timing resolution was 1/3 that of list-mode TOF-OSEM to achieve comparable image quality. While the reconstruction time for list-mode TOF-OSEM depends on the number of events and sizes of the spatial and TOF kernels, the time for DIRECT is independent of these factors. The DIRECT approach is able to reproduce the image quality of the list-mode iterative TOF reconstruction both qualitatively and quantitatively in measured data with a significantly reduced time.
Keywords
biological tissues; expectation-maximisation algorithm; image reconstruction; image sampling; iterative methods; medical image processing; phantoms; positron emission tomography; DIRECT approach; OSEM; UPenn prototype TOF-PET scanner; binned iterative algorithm; confidence-weighted analytic methods; direct image reconstruction; histo-images; image quality; list-mode algorithm; ordered subsets expectation maximization; phantom; reduced angular sampling; time-of-flight PET reconstruction; Image reconstruction; Noise; Phantoms; Spatial resolution; Three dimensional displays; Timing; PET reconstruction; Time-of-flight PET;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
Conference_Location
Knoxville, TN
ISSN
1095-7863
Print_ISBN
978-1-4244-9106-3
Type
conf
DOI
10.1109/NSSMIC.2010.5874184
Filename
5874184
Link To Document