• DocumentCode
    3533071
  • Title

    Suppressing overvoltage on carbodies of a highspeed EMU

  • Author

    Hatsukade, S. ; Fujino, K. ; Kanno, Shota

  • fYear
    2013
  • fDate
    2-6 Sept. 2013
  • Firstpage
    1
  • Lastpage
    9
  • Abstract
    Overvoltage is created on carbodies of a highspeed electric multiple unit (EMU) when the train raises its pantograph or when its main circuit breaker is switched. This paper outlines the mechanism behind the phenomenon of overvoltage generation on carbodies of the highspeed train, proposing suppressing method, and the results of verification of the method. The results indicate the efficiency of the method, where the overvoltage is reduced by 50% from the maximum.
  • Keywords
    circuit breakers; railway electrification; carbodies; circuit breaker; high-speed EMU; high-speed electric multiple unit; high-speed train; overvoltage generation; overvoltage suppression method; pantograph; Cable insulation; Cable shielding; Circuit breakers; Grounding; Rails; Surges; Voltage control; EMC/EMI; Rail vehicle;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Applications (EPE), 2013 15th European Conference on
  • Conference_Location
    Lille
  • Type

    conf

  • DOI
    10.1109/EPE.2013.6631755
  • Filename