4D respiratory motion-corrected Rb-82 myocardial perfusion PET image reconstruction
Author :
Rahmim, Arman ; Tang, Jing ; Ay, M.R. ; Bengel, F.M.
Author_Institution :
Dept. of Radiol., Johns Hopkins Univ., Baltimore, MD, USA
fYear :
2010
fDate :
Oct. 30 2010-Nov. 6 2010
Firstpage :
3312
Lastpage :
3316
Abstract :
Routine clinical myocardial perfusion (MP) PET imaging involves the use of cardiac gating only. Nonetheless, respiratory motion of the heart can considerably degrade the quality of MP images and the quantitative accuracy of myocardial uptake estimates. We first performed a quantitative evaluation of the degrading contributions of cardiac (C) and respiratory (R) motion, as well as non-motion factors of Rb-82 positron range, photon non-collinearity, crystal scattering and penetration. For a normal human simulated phantom, we showed that the combination of all above factors resulted in -48% underestimation of myocardial activity, while corrections for all non-motion factors resulted in 21%, 36% and 41% underestimated myocardial activities in the presence of C, R and C&R motion. This means that compensation for respiratory motion must be considered as critical towards achieving overall motion compensation and/or resolution modeling. To achieve respiratory motion compensation, we used translation motion vectors to first match respiratory-only gated images to the end-expiration reference frame. Next, for each cardiac gate, a 4D EM reconstruction algorithm was applied to the R-gated data within that cardiac phase. Three techniques were compared involving reconstructions of (a) a single R-gate only, and all R-gates (b) without and (c) with respiratory motion correction (MC). Using simulated PET data, quantitative comparisons of noise vs. bias trace-off curves indicated notable improvements for the proposed 4D respiratory MC method. Using CHO analysis as applied to the task of perfusion defect detection, ROC analysis of the three methods resulted in AUC values of 0.610±0.039, 0.645±0.038 and 0.821±0.029. The CLABROC statistical test revealed that the proposed MC technique significantly outperformed the other two methods in the task of defect detection.
Keywords :
data analysis; haemorheology; image reconstruction; image resolution; medical image processing; motion compensation; phantoms; pneumodynamics; positron emission tomography; 4D respiratory motion-corrected image; CLABROC statistical testing; R-gated data; ROC analysis; Rb-82 myocardial perfusion PET reconstruction algorithm; cardiac gating; crystal penetration; crystal scattering; human simulated phantom; image resolution; motion compensation; perfusion defect detection; photon noncollinearity; Computed tomography; Heart; Image reconstruction; Logic gates; Myocardium; Positron emission tomography;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
Conference_Location :
Knoxville, TN
ISSN :
1095-7863
Print_ISBN :
978-1-4244-9106-3
Type :
conf
DOI :
10.1109/NSSMIC.2010.5874417
Filename :
5874417
Link To Document :
بازگشت