DocumentCode
3538593
Title
Space charge formation in XLPE with low frequency AC voltage
Author
Murata, K. ; Tanaka, Y. ; Takada, T.
Author_Institution
Musashi Inst. of Technol., Tokyo, Japan
fYear
1995
fDate
17-20 Sep 1995
Firstpage
419
Lastpage
422
Abstract
To avoid the effect of space charge accumulation, we must find the condition of low frequency AC voltage application which is low enough to apply the withstand voltage test, and high enough to neglect the effect of space charge accumulation in XLPE. In this report, space charge is measured using the pulsed electro-acoustic (PEA) method with low frequency AC voltage application
Keywords
XLPE insulation; acoustoelectric devices; insulation testing; power cable insulation; space charge; XLPE; low frequency AC voltage; power cables; pulsed electro-acoustic method; space charge accumulation; space charge formation; withstand voltage test; Acoustic pulses; Acoustic waves; Cables; Charge measurement; Current measurement; Frequency; Low voltage; Pulse measurements; Space charge; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulating Materials, 1995. International Symposium on
Conference_Location
Tokyo
Print_ISBN
4-88686-047-8
Type
conf
DOI
10.1109/ISEIM.1995.496598
Filename
496598
Link To Document