Title :
Calibration of Line-Scan Cameras
Author :
Luna, Carlos A. ; Mazo, Manuel ; L??zaro, Jos?© Luis ; V??zquez, Juan F.
Author_Institution :
Dept. of Electron., Univ. of Alcala, Alcaláde Henares, Spain
Abstract :
This paper presents a novel method for calibrating line-scan cameras using a calibration pattern comprising two parallel planes with lines that can be described using known equations. Using pattern geometry and a line that is captured by a line-scan camera, we calculate the 3-D coordinates of the points corresponding to the straight lines of a pattern that is captured by the line-scan camera. These coordinates are used to obtain the intrinsic and extrinsic parameters of the line scan using a standard calibration procedure that is based on a recursive least squares method. In this paper, the procedure of calibration and the results obtained for a specific line scan will be shown; specifically, the obtained median residual error is 0.28 pixel. Also, the repetitiveness of the calibration process was verified for a sequence of 500 times.
Keywords :
calibration; cameras; 3D coordinates; calibration pattern; extrinsic parameters; intrinsic parameters; line-scan cameras; parallel planes; pattern geometry; Intrinsic and extrinsic camera parameters; line-scan calibration; optical distortion; perspective projection; pine-hole camera model;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Conference_Location :
10/13/2009 12:00:00 AM
DOI :
10.1109/TIM.2009.2031344