• DocumentCode
    357964
  • Title

    PD characteristics and gas condition in artificially-simulated tree channel

  • Author

    Kaneiwa, Hiroshi ; Suzuoki, Yasuo ; Mizutani, Teruyoshi

  • Author_Institution
    Nagoya Univ., Japan
  • Volume
    1
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    470
  • Abstract
    In order to clarify the mechanisms of partial discharges (PD) in electrical tree, we investigated the effect of channel wall and gas on PD in a void and artificial channels with diameter of 40, 50 and 100 μm. The PD characteristics showed the tree-like PD and PD pulse was suppressed by channel wall for artificial channels with diameter of 40 and 50 pm. The gas volume decreased with PD in artificial channel and void. Furthermore, gas in artificial channel was not consumed more efficiently than that in void. It suggests that the mechanism of the consumption of gas by tree-like PD is different from that by void-like PD
  • Keywords
    partial discharges; trees (electrical); voids (solid); artificial channel; channel wall; electrical tree; gas volume; partial discharge; void; Degradation; Partial discharges; Petroleum; Polymers; Pulse measurements; Time measurement; Trees - insulation; Tungsten; Voltage; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Properties and Applications of Dielectric Materials, 2000. Proceedings of the 6th International Conference on
  • Conference_Location
    Xi´an
  • Print_ISBN
    0-7803-5459-1
  • Type

    conf

  • DOI
    10.1109/ICPADM.2000.875732
  • Filename
    875732