• DocumentCode
    357977
  • Title

    A hybrid system of long term accelerated water tree testing of cables at King Saud university

  • Author

    Al-Arainy, A.A. ; Malik, N.H. ; Qureshi, M.I.

  • Author_Institution
    Dept. of Electr. Eng., King Saud Univ., Riyadh, Saudi Arabia
  • Volume
    1
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    550
  • Abstract
    Instead of traditionally used PVC conduit pipes for long term accelerated aging of polymeric insulated cables, a hybrid system of pipes and small water reservoir tanks connected at the pipe ends was designed and put into operation. Rather than large temperature gradients along the length of water immersed cables, a fairly uniform temperature profile has been achieved in the new set up. This, in combination with the tighter control of multi-factor aging parameters of cables, has alleviated most of the shortcomings related to the conduit pipe aging technique. This paper presents the details of this setup and gives temperature profiles measured during the accelerated aging studies carried out on cable samples
  • Keywords
    XLPE insulation; ageing; insulation testing; life testing; power cable testing; trees (electrical); XLPE; hybrid system; long term accelerated aging; polymeric insulated cables; uniform temperature profile; water reservoir tanks; water tree testing; Accelerated aging; Cable insulation; Life estimation; Plastic insulation; Polymers; Reservoirs; System testing; Temperature measurement; Trees - insulation; Water resources;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Properties and Applications of Dielectric Materials, 2000. Proceedings of the 6th International Conference on
  • Conference_Location
    Xi´an
  • Print_ISBN
    0-7803-5459-1
  • Type

    conf

  • DOI
    10.1109/ICPADM.2000.875753
  • Filename
    875753