• DocumentCode
    3584161
  • Title

    Slow extraction from the Fermilab Main Injector

  • Author

    Moore, C. ; Johnson, D.E. ; Johnstone, J. ; Kobilarcik, T. ; Murphy, C.T.

  • Author_Institution
    Fermi Nat. Accel. Lab., Batavia, IL, USA
  • Volume
    2
  • fYear
    2001
  • fDate
    6/23/1905 12:00:00 AM
  • Firstpage
    1559
  • Abstract
    Slow resonant extraction from the Fermilab Main Injector through the extraction channel was achieved in February 2000, with a spill length of 0.3 sec. Beam losses were small. Excellent wire chamber profiles were obtained and analyzed. The duty factor was not very good and needs to be improved
  • Keywords
    accelerator magnets; electromagnets; particle beam extraction; particle beam focusing; particle beam injection; particle beam stability; proton accelerators; proton beams; synchrotrons; 0.3 s; Fermilab Main Injector; SY120 project; beam emittance; beam losses; beam spill length; duty factor; extraction channel; extraction process; focusing; quadrupoles distribution; slow resonant extraction; wire chamber profiles; Data mining; Electrostatics; Magnetic analysis; Magnetic resonance; Magnetic separation; Particle beam measurements; Particle beams; Power supplies; Size measurement; Wire;