  • Title

    Performance measurements of CMOS SSPM as PET detector

  • Author

    Dokhale, Purushottam ; Nagarkar, Rohan ; Robertson, Rob ; McClish, Mickel ; Stapels, Christopher ; Christian, James ; Entine, Gerald ; Squillante, Michael ; Cherry, Simon ; Shah, Kanai

  • Author_Institution
    Radiat. Monitoring Devices Inc., Watertown
  • Volume
    5
  • fYear
    2007
  • Firstpage
    3224
  • Lastpage
    3228
  • Abstract
    We have designed and developed a complementary metal-oxide-semiconductor (CMOS) solid-state photomultiplier (SSPM). We have studied this novel SSPM as a readout of LYSO scintillator for use in positron emission tomography (PET). Here we present energy resolution, coincidence timing resolution, depth of interaction measurements and flood imaging studies with SSPMs coupled to LYSO seintilators. Two different sizes, 3 x 3 mm2 and 1.5 x 1.5 mm2 SSPMs were studied. The measured FWHM energy resolution with 511 keV gamma rays was 22% for the detector consisting 3 x 3 mm2 SSPM coupled to a 3 x 3 x 15 mm3 LYSO and 11.2 % for the detector consisting 1.5 x 1.5 mm2 SSPM coupled to 1.5 x 1.5 x 10 mm3 LYSO. The timing resolution measured was 1.8 ns for the 3 x 3 mm2 detector in coincidence with a detector consisting LSO coupled to PMT. The coincidence timing resolution was 530 ps for 1.5 x 1.5 mm2 detector. The measured depth-of-interaction resolution by coupling two 1.5 x 1.5 mm2 SSPMs on opposite ends of a 1.5 x 1.5 x 20 mm3 LYSO scintillator was 2.5 mm. The flood histogram was recorded with a 4 x 4 LYSO array, each element measuring 1.5 x 1.5 x 15 mm3 coupled to a position sensitive SSPM (PS-SSPM) consist of a 4 x 4 array of SSPM elements. The flood image was distortion free, all 16 elements were clearly visible and well separated from each other.
  • Keywords
    image resolution; photomultipliers; positron emission tomography; solid scintillation detectors; CMOS SSPM; LYSO scintillator; PET detector; coincidence timing resolution; complementary metal-oxide-semiconductor; depth-of-interaction measurement; electron volt energy 511 keV; energy resolution; flood imaging; performance measurement; positron emission tomography; solid-state photomultiplier; time 1.8 ns; time 530 ps; Energy measurement; Energy resolution; Floods; Gamma ray detection; Gamma ray detectors; Image resolution; Photomultipliers; Positron emission tomography; Solid state circuits; Timing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-0922-8
  • Electronic_ISBN
    1095-7863
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2007.4436826
  • Filename
    4436826