• DocumentCode
    3603209
  • Title

    Online Two-Section PV Array Fault Diagnosis With Optimized Voltage Sensor Locations

  • Author

    Yihua Hu ; Jiangfeng Zhang ; Wenping Cao ; Jiande Wu ; Gui Yun Tian ; Finney, Stephen J. ; Kirtley, James L.

  • Author_Institution
    Dept. of Electron. & Electr. Eng., Univ. of Strathclyde, Glasgow, UK
  • Volume
    62
  • Issue
    11
  • fYear
    2015
  • Firstpage
    7237
  • Lastpage
    7246
  • Abstract
    Photovoltaic (PV) stations have been widely built in the world to utilize solar energy directly. In order to reduce the capital and operational costs, early fault diagnosis is playing an increasingly important role by enabling the long effective operation of PV arrays. This paper analyzes the terminal characteristics of faulty PV strings and arrays, and it develops a PV array fault diagnosis technique. The terminal current-voltage curve of a faulty PV array is divided into two sections, i.e., high-voltage and low-voltage fault diagnosis sections. The corresponding working points of healthy string modules and of healthy and faulty modules in an unhealthy string are then analyzed for each section. By probing into different working points, a faulty PV module can be located. The fault information is of critical importance for the maximum power point tracking and the array dynamical reconfiguration. Furthermore, the string current sensors can be eliminated, and the number of voltage sensors can be reduced by optimizing voltage sensor locations. Typical fault scenarios including monostring, multistring, and a partial shadow for a 1.6-kW 3 $times$ 3 PV array are presented and experimentally tested to confirm the effectiveness of the proposed fault diagnosis method.
  • Keywords
    cost reduction; fault diagnosis; maximum power point trackers; photovoltaic power systems; power generation economics; power generation faults; power generation reliability; sensor placement; solar power; PV module; array dynamical reconfiguration; capital cost reduction; faulty PV string; maximum power point tracking; monostring; multistring; online two-section PV array fault diagnosis; partial shadow; photovoltaic station; power 1.6 kW; solar energy; terminal characterstics; terminal current-voltage curve; voltage sensor location optimisation; Arrays; Circuit faults; Fault diagnosis; Lighting; Low voltage; Temperature; Fault diagnosis; optimization; photovoltaic (PV); photovoltaics; terminal characteristics; voltage sensors;
  • fLanguage
    English
  • Journal_Title
    Industrial Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0046
  • Type

    jour

  • DOI
    10.1109/TIE.2015.2448066
  • Filename
    7128691