Title :
Uniformity of the APD response after irradiation
Author :
A. Gorisek;I. Mandic;S. Korpar;M. Zavrtanik;Y. Musienko;P. Krizan
Author_Institution :
Ljubljana Univ., Slovenia
fDate :
6/26/1905 12:00:00 AM
Abstract :
In 10 years of operation in the CMS electromagnetic calorimeter (ECAL), avalanche photodiodes will be exposed to 1 MeV equivalent neutron fluence of 2middot1013 n/cm2 and total ionization dose of 0.25 Mrad. These APDs are silicon photodiodes operated in avalanche mode. To explore the possibility of usage of these APDs in harsher radiation environments, they were irradiated with reactor neutrons up to 1 MeV equivalent fluence of 5middot1014 n/cm2. This paper reports on measurements of current-voltage characteristics and scan of surface uniformity after irradiation.
Keywords :
"Diodes","Neutrons","Voltage","Collision mitigation","Inductors","Silicon","Dark current","Temperature","Ionization","Current-voltage characteristics"
Conference_Titel :
Nuclear Science Symposium Conference Record, 2004 IEEE
Print_ISBN :
0-7803-8700-7
DOI :
10.1109/NSSMIC.2004.1462557