DocumentCode :
3629483
Title :
The response rate of room temperature terahertz InGaAs-based bow-tie detector with broken symmetry
Author :
I. Kasalynas;D. Seliuta;R. Simniskis;V. Tamosiunas;V. Vaicikauskas;I. Grigelionis;R. Nedzinskas;K. Kohler;G. Valusis
Author_Institution :
Semiconductor Physics Institute, A. Gostauto 11, LT-01108 Vilnius, Lithuania
fYear :
2008
Firstpage :
1
Lastpage :
1
Abstract :
A bow-tie InGaAs with broken symmetry has been designed for terahertz detection at room temperature. An active part of the detector consists of a two-dimensional electron gas which is heated non-uniformly with incident radiation. Main detector performances are operation in a passive scheme, flat frequency response up to 1 THz, the voltage sensitivity of about 5 V/W, the noise equivalent power of roughly 10 nW/Hzfrac12, and the response time less then 7 ns.
Keywords :
"Detectors","Indium gallium arsenide","Laser modes","Temperature sensors","Laser excitation","Optical resonators","Optical transmitters"
Publisher :
ieee
Conference_Titel :
Infrared, Millimeter and Terahertz Waves, 2008. IRMMW-THz 2008. 33rd International Conference on
ISSN :
2162-2027
Print_ISBN :
978-1-4244-2119-0
Electronic_ISBN :
2162-2035
Type :
conf
DOI :
10.1109/ICIMW.2008.4665701
Filename :
4665701
Link To Document :
بازگشت