DocumentCode
3645751
Title
Transient States of the Multiscalar Controlled Double Fed Induction Generator in the Wind Farm
Author
Piotr Kolodziejek
Author_Institution
Control Eng. Dept., Gdansk Univ. of Technol., Gdansk, Poland
Volume
2
fYear
2011
Firstpage
302
Lastpage
307
Abstract
This article presents a detailed model and analysis of wind turbine based on double fed induction generator (DFIG) including cable line to the point of common coupling (PCC). The vector control system is based on the multiscalar model of the machine. Active and reactive power transients on generator terminals and PCC are showed. The cable line parameters influence to the reactive power compensation issues and reactive power compensation limitation related to the rotor current are presented.
Keywords
"Reactive power","Control systems","Voltage fluctuations","Wind farms","Generators","Rotors","Power cables"
Publisher
ieee
Conference_Titel
Machine Learning and Applications and Workshops (ICMLA), 2011 10th International Conference on
Print_ISBN
978-1-4577-2134-2
Type
conf
DOI
10.1109/ICMLA.2011.149
Filename
6147692
Link To Document