DocumentCode
3689546
Title
Comparison of maximum torque per ampere and loss minimization control for the interior permanent magnet synchronous generator
Author
Tin Bariša;Damir Sumina;Martina Kutija
Author_Institution
University of Zagreb, Faculty of Electrical Engineering and Computing, Unska 3, 10000 Zagreb, Croatia
fYear
2015
Firstpage
497
Lastpage
502
Abstract
In this paper maximum torque per ampere and loss minimization control methods for an interior permanent magnet synchronous generator are compared. Permanent magnet synchronous generators have wide application in wind energy conversion systems due to high efficiency, high power density, high power factor and wide speed operating range. Maximum torque per ampere control method finds optimal d-and q-axis stator currents that produce desired electromagnetic torque while minimizing stator current magnitude. Loss minimization control method takes into account both copper and iron losses and finds optimal d- and q-axis stator currents that produce desired electromagnetic torque while minimizing total power loss. Characteristic curves for both control methods considering magnetic saturation are presented. Feed-forward torque control model developed in MATLAB/Simulink was used to verify described control methods.
Keywords
"Stators","Torque","Iron","Electromagnetics","Rotors","Mathematical model","Magnetic flux"
Publisher
ieee
Conference_Titel
Electrical Drives and Power Electronics (EDPE), 2015 International Conference on
Electronic_ISBN
1339-3944
Type
conf
DOI
10.1109/EDPE.2015.7325344