• DocumentCode
    3692377
  • Title

    Vector flow imaging of the ascending aorta

  • Author

    Kristoffer Lindskov Hansen;Hasse Møller-Sørensen;Jesper Kjaergaard;Maiken Brit Jensen;Jens Teglgaard Lund;Michael Bachmann Nielsen;Jørgen Arendt Jensen

  • Author_Institution
    University Hospital of Copenhagen, Denmark
  • fYear
    2015
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    In the ascending aorta, atherosclerotic plaque formation, which is a risk factor for cerebrovascular events, most often occurs along the inner curvature. Atherosclerosis is a multifactorial disease, but the predilection site for the aortic vessel degradation is probably flow dependent. To better understand the aortic flow and especially the complex flow patterns, the ascending aorta was scanned intraoperatively in patients undergoing heart surgery using the angle-independent vector velocity ultrasound method Transverse Oscillation (TO). The primary aim of the study was to analyze systolic backflow in relation to atherosclerosis. Thirteen patients with normal aortic valves were included in to the study. TO implemented on a conventional US scanner (ProFocus 2202 UltraView, BK Medical, Herlev, Denmark) with a linear array transducer (8670, BK Medical, Herlev, Denmark) was used intraoperatively on the ascending aorta in long axis view. The presence of systolic backflow, visualized with TO, was correlated to aortic atherosclerosis, to systolic velocities obtained with transesophageal echocardiography and cardiac output obtained with pulmonary artery catheter thermodilution, to gender, age, aortic diameter, left ventricular ejection fraction (LVEF) and previous myocardial infarctions (MI). Systolic backflow in the ascending aorta was present for 38% (n=5) of the patients. The location of the backflow was strongly associated to the location of the plaques (p<;0.005), and backflow was associated to high systolic velocities (p<;0.05). The other obtained parameters were not associated to systolic backflow. It was shown that systolic backflow is a common flow feature in the ascending aorta, and that backflow is associated to atherosclerotic plaques and systolic velocities. The study indicates that vector flow imaging using TO can provide important blood flow information in the assessment of atherosclerosis.
  • Keywords
    "Atherosclerosis","Biomedical imaging","Blood flow","Ultrasonic imaging","Transducers","Diseases"
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2015 IEEE International
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2015.0069
  • Filename
    7329368