DocumentCode
3693717
Title
Investigation of space passive hydrogen maser atomic beam formation system life-time
Author
A. Pavlenko;K. Pavlenko
Author_Institution
JSC ?Vremya-CH? Nizhny Novgorod, Russia
fYear
2014
fDate
6/1/2014 12:00:00 AM
Firstpage
130
Lastpage
132
Abstract
For SPHM life-time the most critical part is atomic beam formation system. Two special set-ups were made to evaluate necessary amount of hydrogen in H2-source and ability of evacuation system to absorb required amount of hydrogen. The experiment has shown that both systems restrict SPHM life time with a period of more than 15 years.
Keywords
"Hydrogen","Current measurement","Gettering","Pressure measurement","Valves","Volume measurement","Pressure gauges"
Publisher
ieee
Conference_Titel
European Frequency and Time Forum (EFTF), 2014
Type
conf
DOI
10.1109/EFTF.2014.7331444
Filename
7331444
Link To Document