DocumentCode
3693823
Title
Ultra compact reference ULE cavity
Author
A. Didier;J. Millo;C. Lacro?te;V. Giordano;E. Rubiola;Y. Kersal?;M. Ouisse;J. Delporte
Author_Institution
FEMTO-ST Institute, Time and Frequency Dpt., UMR 6174 CNRS-ENSMM-UFC-UTBM, 26 rue de l´Epitaphe, 25030 Besan?on Cedex, France
fYear
2014
fDate
6/1/2014 12:00:00 AM
Firstpage
514
Lastpage
517
Abstract
In this paper, we present a new Fabry-Perot cavity design that will be used as a compact reference. The mechanical and thermal simulations that led to the design of the cavity are described. The vacuum chamber and thermal shields around the cavity are also presented.
Keywords
"Cavity resonators","Acceleration","Thermal stability","Sensitivity","Optical sensors","Optical attenuators","Stability analysis"