    Grid to plate current-voltage characteristics of a corona triode

  • Author

    O. N. Oliveira;G. F. Leal Ferreira

  • Author_Institution
    Instituto de Fí
  • fYear
    1985
  • Firstpage
    500
  • Lastpage
    505
  • Abstract
    Measurements of the grid to plate current-voltage characteristics of the corona triode are reported. A space charge limited current (SCLC) characteristic is observed to hold for low values of the plate current Ip, provided that the grid voltage Vg is corrected by a counter potential Vr. The analysis of experimental results indicates that Vr is due both to penetration of field lines through the grid and to the corona wind. However, departure from SCLC regime is observed at higher plate currents. In the calculation, a layer of recombination centers is substituted for the grid. The model fits the whole characteristics and leads to reasonable values of the parameters defined by the model.