DocumentCode
3700837
Title
Grid to plate current-voltage characteristics of a corona triode
Author
O. N. Oliveira;G. F. Leal Ferreira
Author_Institution
Instituto de Fí
fYear
1985
Firstpage
500
Lastpage
505
Abstract
Measurements of the grid to plate current-voltage characteristics of the corona triode are reported. A space charge limited current (SCLC) characteristic is observed to hold for low values of the plate current Ip, provided that the grid voltage Vg is corrected by a counter potential Vr. The analysis of experimental results indicates that Vr is due both to penetration of field lines through the grid and to the corona wind. However, departure from SCLC regime is observed at higher plate currents. In the calculation, a layer of recombination centers is substituted for the grid. The model fits the whole characteristics and leads to reasonable values of the parameters defined by the model.
Keywords
"Corona","Electric potential","Current measurement","Radiation detectors","Space charge","Ions","Electrodes"
Publisher
ieee
Conference_Titel
Electrets (ISE 5), 1985 5th International Symposium on
Print_ISBN
000-0-0000-0000-0
Type
conf
DOI
10.1109/ISE.1985.7341528
Filename
7341528
Link To Document