DocumentCode :
3711122
Title :
On-site detection of defective panels in mega solar systems by handy electroluminescence surveillance
Author :
Takashi Fuyuki;Tsuyoshi Tomimoto;Ayumi Tani;Yasuaki Ishikawa
Author_Institution :
Nara Institute of Science and Technology, 8916-5, Takayama, Ikoma, 630-0192 JAPAN
fYear :
2015
fDate :
6/1/2015 12:00:00 AM
Firstpage :
1
Lastpage :
3
Abstract :
Accurate and quick evaluation methods of PV panels and systems are strongly required especially for installed mega-solar systems in order to maintain the long reliable performance. On-site evaluation can be available using the devised power source units and cost effective Si sensor cameras. Portable and handy EL systems will promote the surveillance of installed PV systems.
Keywords :
"Cameras","Solar system","Circuit faults","Photovoltaic cells","Silicon","Electroluminescence","Reliability"
Publisher :
ieee
Conference_Titel :
Photovoltaic Specialist Conference (PVSC), 2015 IEEE 42nd
Type :
conf
DOI :
10.1109/PVSC.2015.7355838
Filename :
7355838
Link To Document :
بازگشت