• DocumentCode
    3711989
  • Title

    New shunt calorimeter for testing electric motors

  • Author

    L. Aarniovuori;W. Cao;H. Chen;N. Yang

  • Author_Institution
    Electrical Engineering, LUT School of Energy Systems, Lappeenranta, Finland
  • fYear
    2015
  • Firstpage
    1
  • Lastpage
    8
  • Abstract
    The determination of the power losses in the high-efficiency electric motors with distorted voltage and current waveforms is technically challenging and thus an alternative using the calorimetric measurement systems is gaining in popularity. Different types of calorimetric systems with their pros and cons have been proposed in the literature but they are generally limited in measurement accuracy and control complexity. This paper proposes a new shunt calorimeter used for measuring power losses in electrical motors to a high accuracy of 0.2%.
  • Keywords
    "Loss management","Voltage measurement","Energy efficiency","Electrical equipment","Thermal analysis"
  • Publisher
    ieee
  • Conference_Titel
    Industry Applications Society Annual Meeting, 2015 IEEE
  • Type

    conf

  • DOI
    10.1109/IAS.2015.7356742
  • Filename
    7356742