• DocumentCode
    3718303
  • Title

    A novel processing concept for reduction of substrate artifacts in ultrasound transducer arrays

  • Author

    Angel Savov;Adnan Haider Noor;Ronald Dekker

  • Author_Institution
    Materials innovation institute (M2i), High Tech Campus 4, 5656AE Eindhoven, The Netherlands
  • fYear
    2015
  • Firstpage
    145
  • Lastpage
    148
  • Abstract
    Free-standing tungsten membranes supported by polyimide pillars were fabricated, demonstrating the general feasibility of the process. To reduce the warping due to the stress in the deposited tungsten layer four different membrane shapes were tested. The type B membrane shape gave the best result with the average peak to thorough distance of 162 nm. While the result is encouraging, the warping is still posing risk to the reliable operation of the CMUT since the gap of the transducer that is to be fabricated on the membrane is on the same order of magnitude.
  • Keywords
    "Transducers","Substrates","Stress","Ultrasonic imaging","Tungsten","Fabrication","Acoustics"
  • Publisher
    ieee
  • Conference_Titel
    Microsystems, Packaging, Assembly and Circuits Technology Conference (IMPACT), 2015 10th International
  • Print_ISBN
    978-1-4673-9690-5
  • Type

    conf

  • DOI
    10.1109/IMPACT.2015.7365191
  • Filename
    7365191