DocumentCode
3718303
Title
A novel processing concept for reduction of substrate artifacts in ultrasound transducer arrays
Author
Angel Savov;Adnan Haider Noor;Ronald Dekker
Author_Institution
Materials innovation institute (M2i), High Tech Campus 4, 5656AE Eindhoven, The Netherlands
fYear
2015
Firstpage
145
Lastpage
148
Abstract
Free-standing tungsten membranes supported by polyimide pillars were fabricated, demonstrating the general feasibility of the process. To reduce the warping due to the stress in the deposited tungsten layer four different membrane shapes were tested. The type B membrane shape gave the best result with the average peak to thorough distance of 162 nm. While the result is encouraging, the warping is still posing risk to the reliable operation of the CMUT since the gap of the transducer that is to be fabricated on the membrane is on the same order of magnitude.
Keywords
"Transducers","Substrates","Stress","Ultrasonic imaging","Tungsten","Fabrication","Acoustics"