Method to Minimize the Low-Frequency Neutral-Point Voltage Oscillations With Time-Offset Injection for Neutral-Point-Clamped Inverters
Author
Ui-Min Choi ; Blaabjerg, Frede ; Kyo-Beum Lee
Author_Institution
Dept. of Energy Technol., Aalborg Univ., Aalborg, Denmark
Volume
51
Issue
2
fYear
2015
fDate
March-April 2015
Firstpage
1678
Lastpage
1691
Abstract
This paper proposes a method to reduce the low-frequency neutral-point voltage oscillations. The neutral-point voltage oscillations are considerably reduced by adding a time offset to the three-phase turn-on times. The proper time offset is simply calculated considering the phase currents and dwell time of small- and medium-voltage vectors. However, if the power factor is lower, there is a limitation to eliminate neutral-point oscillations. In this case, the proposed method can be improved by changing the switching sequence properly. Additionally, a method for neutral-point voltage balancing is also proposed. The change in switching frequency by the proposed method and its effects on the outputs are negligible. Simulation and experimental results verify the validity and feasibility of the proposed strategy.
Keywords
circuit oscillations; invertors; low-frequency neutral-point voltage oscillations; medium-voltage vectors; neutral-point-clamped inverters; power factor; small-voltage vectors; time-offset injection; Integrated circuits; Inverters; Modulation; Oscillators; Switches; Switching loss; Vectors; Low-frequency oscillations; T-type inverter; multilevel; neutral-point clamped (NPC) inverter; neutral-point voltage balancing; three-level inverter;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/TIA.2014.2350079